Direct control of this one unit, plus its live readings.
- Speed drag from 0 to 5: 0 turns the fan off and 1–5 are the levels; a change here is a per-unit override that holds until you set the group's mode again, and marks this unit as Manual.
- Direction Supply pulls fresh air in, Extract pushes stale air out; for automatic supply↔extract alternation choose Auto or Exchange on the group rather than holding a direction here.
- Timer The timers that include this unit are listed here. Add Timer starts a new one with only this unit ticked. Adding a timer is PREMIUM.
- Sensors live temperature, humidity, the VOC air-quality index (higher is worse), and the current direction.
- Filter alarm shown only when the unit reports a clogged filter; tap Reset after you replace it.
- Details the unit's IP, MAC, firmware, brand, model and online state; Master/Slave roles aren't shown here, you assign those in Groups.